Weider 400 User Manual

Browse online or download User Manual for Fitness, gymnastics & weight training Weider 400. TECHNICAL DATA WEIDER – Heat Pumps

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
TECHNICAL DATA WEIDER – Heat Pumps
HEAT PUMP TYPE SW500 SW600 2SW500 2SW600
GROUNDWATER OPERATION with a feed temperature of 10 °C and heating flow temperature of 35 and 50 °C
BRINE OPERATION with a feed temperature of 0 °C and heating flow temperature of 35 and 50°C
JOINT DATA for groundwater and brine operation
*
* delayed engagement of the second compressor Subject to alterations
Electrical protection system: IP41 Date 12/2010
Heat exchanger: material no.1.4401, V4A steel made of chromium-nickel-molybdenum
Version 4.3 WT08
°C
35 50 35 50 35 50 35 50
Heating output kW
47 43 58 53 94 86 116 106
Electric power consumption kW
7,8 10,8 9,7 13,3 15,6 21,6 19,4 26,6
Coefficient of performance (t 10 K)
6 4,0 6 4,0 6 4,0 6 4,0
Coefficient of performance (t 5 K)
5,6 3,5 5,6 3,5 5,6 3,5 5,6 3,5
Volume flow rate - groundwater m³/h
10 12 20 24
Pressure drop - evaporator mbar
260 260 260 260
Temperature range - groundwater °C
+ 7 to +20
°C
35 50 35 50 35 50 35 50
Heating output kW
36 33 44 40 72 66 88 80
Electric power consumption kW
7,8 11 9,6 13,3 15,6 22 19,2 26,6
Coefficient of performance (t 10 K)
4,6 3,0 4,6 3,0 4,6 3,0 4,6 3,0
Coefficient of performance (t 5 K)
4,3 2,6 4,3 2,6 4,3 2,6 4,3 2,6
Volume flow rate - brine m³/h
8 10 16 20
Pressure drop (25% ethylene gl.) mbar
190 200 190 200
Temperature range - brine °C -6° to +20
Volume flow rate - heating water m³/h
4 to 8 5 to 11 8,1 10,3
Pressure drop - heating water mbar
40 to 150 40 to 150 300 340
Temperature difference Δt °C 5 to 10 5 to 10 7 to 10 7 to 10
Flow temperature °C 25 to 55° (at ground water up to 60°)
Mains connection V
2x 3 x
230/400
2 x 3 x
230/400
3 x 3 x
230/400
3 x 3 x
230/400
Operating current max. A
25 32 50 64
Electric power consumption max. kW
13,6 17,1 27,2 34,2
Starting current A
167 198 192 230
Pre-fuse, external A
3x13/ 3x32 3x13/ 3x32
3x13/
2x3x32
3x13/
2x3x32
Approx. weight (complete) kg
400 450 800 900
Refrigerant R407C kg
6,6 8,8 13,2 17,6
140
1110
1310
1200
690
870
Tiefe 785 mm
255
5
2SW500
2SW600
Aufstellung der Module
nebeneinander
Ansicht Rückseite
1 = Vorlauf Heizung
2= Rücklauf Heizung
3 = Ablauf Kaltwasser
4 = Zulauf Kaltwasser
5 = Elektroanschl
alle 6/4" Aussengewinde
3 2
4 1
5 5
SW500
SW600
3 2
4 1
3 2
4 1
500
At groundwater
operation it is neces-
sary to use a secon-
dary heat loop for
these types of heat
pumps.
Depth 520 mm
View of rear panel
1 = Heating flow
2 = Heating return
3 = Cold water discharge
4 = Cold water supply
5 = Electrical connections
all 6/4”
Modules installed side by side